ADC KENTROX DATASMART T3/E3 SMDSU MODEL 1596X (DC POWER) Card Type T3/E3 CSU/DSU Chipset Unidentified T3/E3 Transfer Rate 34.368Mbps (E3) /44.736Mbps (T3) T3/E3 Protocol M13, C-Bit, G.751, B8ZS Frame Type Unidentified Data Bus Serial [Image] CONNECTIONS Function Label Function Label Monitor jack CN1 T3/E3 line in/out CN8 Monitor jack CN2 T3/E3 line in/out CN9 DCE serial control CN3 RS-422 auxiliary clock CN10 port port DTE serial control CN4 Alarm cutoff switch S5 port V.35 serial data port CN5 DC power in (see SC1 via DB-25 connector pinout below) HSSI serial data port CN6 Alarm relay (see SC2 pinout below) HSSI serial data port CN7 Note:Standard V.35 serial port is provided on an included adapter cable. SC1 PINOUT Function Screw Function Screw -40V to -56VDC power in 1 +40 to +56VDC power in 3 Ground 2 SC2 PINOUT Function Screw Function Screw Normally closed contact 1 Normally open contact 3 Signal common 2 USER CONFIGURABLE SETTINGS Setting Label Position » Control port parity disabled S1/3 On Control port parity enabled S1/3 Off » Control port parity set to odd S1/4 On Control port parity set to even S1/4 Off » Control port uses 8 data bits S1/5 On Control port uses 7 data bits S1/5 Off » Control port uses 1 stop bit S1/6 On Control port uses 2 stop bits S1/6 Off » Alarm reporting disabled S1/7 On Alarm reporting enabled S1/7 Off » Alarm reporting output to DCE control S1/8 On port Alarm reporting output to DTE control S1/8 Off port » Adapter in SMDS mode S2/3 On Adapter in DSU mode S2/3 Off » T3/E3 receive equalization enabled S2/4 On T3/E3 receive equalization disabled S2/4 Off » T3/E3 transmit Line Build Out out S2/5 On T3/E3 transmit Line Build Out in S2/5 Off » Factory configured - do not alter S2/6 On » Factory configured - do not alter S2/7 On » Factory configured - do not alter S2/8 On CONTROL PORT SPEED SELECTION Setting S1/1 S1/2 » 9600bps On On 4800bps On Off 2400bps Off On 1200bps Off Off PROTOCOL SELECTION Setting S2/1 S2/2 » T3 MI3 On On T3 C-Bit On Off E3 G.751 Off On E3 G.751 Off Off THUMBWEEL FUNCTION SELECTION Function S3 S4 S5 Reset loopback tests Pushed Position 0 Not pushed Begin remote line loopback Pushed Position 1 Not pushed test Begin remote payload Pushed Position 2 Not pushed loopback test Reset to factory defaults Pushed for Position 3 Pushed for and switch settings 2 sec. 2 sec. Begin near-end line loopback Pushed Position 4 Not pushed test Begin near-end payload Pushed Position 5 Not pushed loopback test Begin near-end local Pushed Position 6 Not pushed loopback test Begin data near-end terminal Pushed Position 7 Not pushed loopback test Reset SMDSU address to Pushed for Position 7 Pushed for 00:00:000 2 sec. 2 sec. Note:S3 and S5 must always be held for at least one-half of one second for the above functions to take effect. DIAGNOSTIC LED(S) LED Color Status Condition PWR Green On Power is on PWR Red On Self-test failed PWR N/A Off Power is off LOOP Yellow On Local loopback test in progress LOOP Yellow Blinking Remote loopback test in progress LOOP Yellow Off Loopback test not in progress SEND Yellow On Test code being sent SEND Yellow Blinking Remote loopback test may be in progress but cannot be verified SEND Yellow Off Test code not being sent ALM Red On Alarm condition detected and awaiting user intervention ALM Green On Alarm condition detected; user intervention in progress ALM N/A Off Alarm condition not detected RCV Green On DSU is receiving data from network RCV Green Off DSU is not receiving data from network XMT Green On DSU is transmitting data to network XMT Green Off DSU is not transmitting data to network FEI Red On Remote is out of PLCP lock FEI Red Blinking Remote PLCP Code Violation detected FEI Red Off Remote PLCP normal NEI Red On Local DSU is out of PLCP lock NEI Red Blinking Local DSU PLCP Code Violation detected NEI Red Off Local DSU PLCP normal TXD Yellow On Control port is transmitting data TXD Yellow Off Control port is not transmitting data DIAGNOSTIC LED(S) (CON’T) LED Color Status Condition RXD Yellow On Control port is receiving data RXD Yellow Off Control port is not receiving data TA Yellow On V.24 DTR or V.35 TA signal is high TA Yellow Off V.24 DTR or V.35 TA signal is low CA Yellow On V.24 DCD or V.35 CA signal is high CA Yellow Off V.24 DCD or V.35 CA signal is low DATA Green On Valid data signal detected DATA Green Off No valid signal detected CV Red On Code Violation error detected CV Red Off Code Violation error not detected LOS Red On Loss Of Signal condition detected LOS Red Off Loss Of Signal condition not detected OOF Red On Signal is out of frame synchronization OOF Red Off Signal is not out of frame synchronization AIS Red On Alarm Indication Signal condition detected AIS Red Off Alarm Indication Signal condition not detected YEL Yellow On Remote Yellow Alarm condition detected YEL Yellow Blinking Local Yellow Alarm condition detected YEL Yellow Off Yellow Alarm condition not detected